Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Oncol ; 13: 1161738, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37554160

RESUMO

Objectives: Colorectal cancer (CRC) is a serious challenge for the health system. In 2022 CRC represented 8% of cancer diagnoses in the United States. 30% of patients already show metastases at the initial tumor staging. The majority of these metastases are sited in the liver. According to their extension and the status of the tumor colorectal liver metastases can be treated in several ways, with hepatic resection being the gold-standard. Contrast-enhanced computed tomography (CE-CT), positron emission tomography/computed tomography (PET/CT) and magnetic resonance imaging (MRI) can be used for evaluation of resectability of these liver metastases. The aim of this study is to assess the most economic imaging modality for detecting liver metastases eligible for hepatic resection by analyzing their cost-effectiveness. Materials and methods: In our study, a Markov state transition model was built to calculate the quality-adjusted life years (QALYs) and overall costs for each diagnostic strategy in accord with the stated input values obtained from scientific research. Further, probabilistic sensitivity analyses by means of Monte Carlo simulations were performed to consider possible model uncertainties. For evaluation of the cost-effectiveness on an economic threshold, the Willingness-to-pay (WTP) was set at $ 100,000. The applied values and the calculated results are based on the U.S. healthcare system. Results: CE-CT led to overall costs of $ 42,874.02 and 8.47 QALYs, whereas MRI led to $ 40,863.65 and 8.50 QALYs. PET/CT resulted in overall costs of $ 43,216.74 and 8.48 QALYs. Therefore, MRI was determined to be the dominant strategy in the model. According to the performed sensitivity analyses, MRI remained cost-effective over a wide range of WTPs. Conclusion: In conclusion, according to our analysis, MRI is the dominant strategy for detecting hepatic metastases eligible for hepatic resection in colorectal cancer.

2.
Eur Radiol ; 33(11): 7840-7848, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37338555

RESUMO

OBJECTIVES: To investigate the effect of a device-assisted suction against resistance Mueller maneuver (MM) on transient interruption of contrast (TIC) in the aorta and pulmonary trunk (PT) on computed tomography pulmonary angiogram (CTPA). METHODS: In this prospective single-center study, 150 patients with suspected pulmonary artery embolism were assigned randomly with two different breathing maneuvers (Mueller maneuver (MM) or standard end-inspiratory breath-hold command (SBC)) during routine CTPA. The MM was performed using a patented prototype (Contrast Booster™) which allows both the patient by means of visual feedback and the medical staff in the CT scanning room to monitor whether the patient is sucking sufficiently or not. Mean Hounsfield attenuation in descending aorta and PT was measured and compared. RESULTS: Overall, patients with MM showed an attenuation of 338.24 HU in the pulmonary trunk, compared to 313.71 HU in SBC (p = 0.157). In the aorta, the values for MM were lower compared to SBC (134.42 HU vs. 177.83 HU, p = 0.001). The TP-aortic ratio was significantly higher in the MM group at 3.86 compared to the SBC group at 2.26, p = 0.001. TIC phenomenon was absent in the MM group, whereas it was present in 9 patients (12.3%) in the SBC group (p = 0.005). Overall contrast was better on all levels for MM (p < 0.001). The presence of breathing artifacts was higher in the MM group (48.1% vs. 30.1%, p = 0.038), without clinical consequence. CONCLUSIONS: Performing the MM with the application of the prototype is an effective way of preventing the TIC phenomenon during i.v. contrast-enhanced CTPA scanning compared to the standard end-inspiratory breathing command. CLINICAL RELEVANCE: Compared to standard end-inspiratory breathing command, the device-assisted Mueller maneuver (MM) improves contrast enhancement and prevents the transient interruption of contrast (TIC) phenomenon in CTPA. Therefore, it may offer optimized diagnostic workup and timely treatment for patients with pulmonary embolism. KEY POINTS: • Transient interruption of contrast (TIC) may impair image quality in CTPA. • Mueller Maneuver using a device prototype could lower the rate of TIC. • Device application in clinical routine may increase diagnostic accuracy.


Assuntos
Embolia Pulmonar , Tomografia Computadorizada por Raios X , Humanos , Sucção , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Meios de Contraste
3.
Eur J Radiol ; 163: 110803, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37004464

RESUMO

OBJECTIVES: Colorectal cancers (CRC) are among the world's most prevailing cancer entities. In a third of all cases, the patients have already developed distant metastases - mainly in the liver - at the time of detection. Colorectal liver metastases (CRLM) can be treated by surgical resection or, as is possible in most cases, by percutaneous ablation. For selecting the liver metastases eligible for radiofrequency ablation (RFA) or microwave ablation (MWA), the common imaging modalities are magnetic resonance imaging (MRI), positron emission tomography/computed tomography (PET/CT), and contrast-enhanced computed tomography (CE-CT). This study aims to evaluate those imaging modalities for selecting liver lesions eligible for ablation according to their long-term cost-effectiveness. MATERIALS AND METHODS: A Markov model was applied, calculating quality-adjusted life years (QALYs) and accumulative costs for every diagnostic strategy, according to predefined input parameters obtained from published research. Further, sensitivity analyses were executed to prove the certainty of the calculations by running Monte-Carlo simulations with 30,000 reiterations. The Willingness-to-pay (WTP) is at $ 100,000. All calculations are based on the U.S. healthcare system. RESULTS: CE-CT caused cumulative costs of $ 31,940.98 and 8,99 QALYs, whereas MRI caused $ 32,070.83 and 9,01 QALYs. PET/CT caused cumulative costs of $ 33,013.21 and 8,99 QALYs. CONCLUSION: In conclusion, according to our analysis, MRI is the most cost-effective strategy for detecting liver metastases eligible for ablation and therefore should be seen as the gold standard.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18 , Análise Custo-Benefício , Análise de Custo-Efetividade , Tomografia Computadorizada por Raios X/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Tomografia por Emissão de Pósitrons/métodos
4.
Cancers (Basel) ; 14(9)2022 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-35565365

RESUMO

BACKGROUND: For patients with solid renal masses, a precise differentiation between malignant and benign tumors is crucial for forward treatment management. Even though MRI and CT are often deemed as the gold standard in the diagnosis of solid renal masses, CEUS may also offer very high sensitivity in detection. The aim of this study therefore was to evaluate the effectiveness of CEUS from an economical point of view. METHODS: A decision-making model based on a Markov model assessed expenses and utilities (in QALYs) associated with CEUS, MRI and CT. The utilized parameters were acquired from published research. Further, a Monte Carlo simulation-based deterministic sensitivity analysis of utilized variables with 30,000 repetitions was executed. The willingness-to-pay (WTP) is at USD 100,000/QALY. RESULTS: In the baseline, CT caused overall expenses of USD 10,285.58 and an efficacy of 11.95 QALYs, whereas MRI caused overall expenses of USD 7407.70 and an efficacy of 12.25. Further, CEUS caused overall expenses of USD 5539.78, with an efficacy of 12.44. Consequently, CT and MRI were dominated by CEUS, and CEUS remained cost-effective in the sensitivity analyses. CONCLUSIONS: CEUS should be considered as a cost-effective imaging strategy for the initial diagnostic workup and assessment of solid renal masses compared to CT and MRI.

5.
Eur J Radiol ; 146: 110105, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34920293

RESUMO

The development towards targeted treatments in oncology has been accompanied by significant improvements in molecular imaging. Yet, broad application of novel imaging techniques has partly been slowed down due to economical considerations. Building on the broad positive evidence of its diagnostic accuracy, modelling of effects on long-term costs and effectiveness may help to foster a broader application and acceptance of comprehensive molecular imaging techniques, such as PET/MRI. In this article, common economic evaluation techniques and cost-effectiveness analysis (CEA) evaluation methods will be introduced including Markov models and incremental cost-effectiveness ratios (ICER). This is complemented with a review of literature on recently published cost-effectiveness of molecular imaging. Additionally, the strategic relevance of CEAs for the molecular imaging community is discussed and combined with a global outlook.


Assuntos
Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Análise Custo-Benefício , Humanos , Imagem Molecular , Anos de Vida Ajustados por Qualidade de Vida
6.
Diagnostics (Basel) ; 11(2)2021 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-33670457

RESUMO

Neuroendocrine tumors (NETs) are relatively rare neoplasms arising from the hormone-producing neuroendocrine system that can occur in various organs such as pancreas, small bowel, stomach and lung. As the majority of these tumors express somatostatin receptors (SSR) on their cell membrane, utilization of SSR analogs in nuclear medicine is a promising, but relatively costly approach for detection and localization. The aim of this study was to analyze the cost-effectiveness of 68Ga-DOTA-TATE PET/CT (Gallium-68 DOTA-TATE Positron emission tomography/computed tomography) compared to 111In-pentetreotide SPECT/CT (Indium-111 pentetreotide Single Photon emission computed tomography/computed tomography) and to CT (computed tomography) alone in detection of NETs. A decision model on the basis of Markov simulations evaluated lifetime costs and quality-adjusted life years (QALYs) related to either a CT, SPECT/CT or PET/CT. Model input parameters were obtained from publicized research projects. The analysis is grounded on the US healthcare system. Deterministic sensitivity analysis of diagnostic parameters and probabilistic sensitivity analysis predicated on a Monte Carlo simulation with 30,000 reiterations was executed. The willingness-to-pay (WTP) was determined to be $ 100,000/QALY. In the base-case investigation, PET/CT ended up with total costs of $88,003.07 with an efficacy of 4.179, whereas CT ended up with total costs of $88,894.71 with an efficacy of 4.165. SPECT/CT ended up with total costs of $89,973.34 with an efficacy of 4.158. Therefore, the strategies CT and SPECT/CT were dominated by PET/CT in the base-case scenario. In the sensitivity analyses, PET/CT remained a cost-effective strategy. This result was due to reduced therapy costs of timely detection. The additional costs of 68Ga-DOTA-TATE PET/CT when compared to CT alone are justified in the light of potential savings in therapy costs and better outcomes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...